Resting voltage, 12 V lead-acid bank
- 12.7 V or more: fully charged
- About 12.4 V: roughly three-quarters
- About 12.2 V: roughly half, time to find out why
- 12.0 V and below: deeply discharged, damage risk
Two banks, two jobs
The house bank runs the yacht’s systems; the start bank only has to start the engines. A start bank that drifts down while the yacht sits usually means something is drawing current that should not be.
24 V systems and lithium
On a 24 V bank the figures roughly double. Lithium batteries hold a flatter voltage curve, so thresholds are set differently; we set them per yacht at installation.
When the app warns you
By default a house bank below about 12.2 V raises a warning, and a deeper drop raises a critical alert. The usual cause is lost shore power, which is why both are watched together.